Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Microcomputed Tomographic Analysis of the Peri-Implant Bone
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 24 , Issue 4
July/August 2004

Pages 316–325


Microcomputed Tomographic Analysis of the Peri-Implant Bone

Alberto Rebaudi, MD, DDS/Bruno Koller, Dr Sc Techn, PhD/Andres Laib, Dr Sc Nat, PhD/Paolo Trisi, DDS, PhD


PMID: 15446401
DOI: 10.11607/prd.00.0594

A recently developed technology allows evaluation of bone biopsies with 3-D microcomputed tomography (microCT). The present study evaluated the feasibility of application of microCT to the analysis of peri-implant bone tissues. A human bone biopsy containing a titanium screw was analyzed using a microCT scan. The parameters computed by the microCT were bone volume, bone surface, trabecular thickness, trabecular separation, and bone connectivity. Also, the bone-to-implant apposition was measured, and all results were compared with those obtained with standard histomorphometry of the same biopsy. The results of the present study suggest that microCT enables 3-D nondestructive evaluation of bone biopsies containing endosseous titanium implants, also allowing analysis of the bone-implant interface. Measurements of bone-to-implant apposition obtained by microCT were similar to those obtained with standard undecalcified histology. (Int J Periodontics Restorative Dent 2004;24:316–325)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help